Previous: Floating Point Parameters, Up: Floating Type Macros   [Contents][Index]


A.5.3.3 IEEE Floating Point

Here is an example showing how the floating type measurements come out for the most common floating point representation, specified by the IEEE Standard for Binary Floating Point Arithmetic (ANSI/IEEE Std 754-1985). Nearly all computers designed since the 1980s use this format.

The IEEE single-precision float representation uses a base of 2. There is a sign bit, a mantissa with 23 bits plus one hidden bit (so the total precision is 24 base-2 digits), and an 8-bit exponent that can represent values in the range -125 to 128, inclusive.

So, for an implementation that uses this representation for the float data type, appropriate values for the corresponding parameters are:

FLT_RADIX                             2
FLT_MANT_DIG                         24
FLT_DIG                               6
FLT_MIN_EXP                        -125
FLT_MIN_10_EXP                      -37
FLT_MAX_EXP                         128
FLT_MAX_10_EXP                      +38
FLT_MIN                 1.17549435E-38F
FLT_MAX                 3.40282347E+38F
FLT_EPSILON             1.19209290E-07F

Here are the values for the double data type:

DBL_MANT_DIG                         53
DBL_DIG                              15
DBL_MIN_EXP                       -1021
DBL_MIN_10_EXP                     -307
DBL_MAX_EXP                        1024
DBL_MAX_10_EXP                      308
DBL_MAX         1.7976931348623157E+308
DBL_MIN         2.2250738585072014E-308
DBL_EPSILON     2.2204460492503131E-016